C300 V1.2.0开局指导书 下载本文

内容发布更新时间 : 2024/5/18 7:57:22星期一 下面是文章的全部内容请认真阅读。

版本与主用板上的版本同步一致。 ZXAN#show version-saved master

PhyLoc FileName VerType VerTag BuildTime VerLenth Active --------------------------------------------------------------------------------

1/1/11 gtgoa.bt BT V1.0.0P1 2010-07-01 13:42:04 326048 0 1/1/11 gtgoa.fw FW V1.2.0 2010-09-06 16:00:35 5437973 0 1/1/11 gtgoa.mvr MVR V1.2.0 2010-09-06 16:00:33 1206069 0 1/1/11 gtgoc.bt BT V1.0.0P1 2010-11-15 14:22:39 315344 0 1/1/11 gtgoc.fw FW V1.2.0 2010-09-06 15:42:25 13888707 0 1/1/11 gtgoc.mvr MVR V1.2.0 2010-09-06 15:42:14 1302608 0 1/1/11 gucd.bt BT V1.0.0P2 2010-12-20 09:05:00 210876 0 1/1/11 gucd.fw FW V1.2.0 2010-12-21 17:18:16 104625 0 1/1/11 gucd.mvr MVR V1.2.0 2010-12-21 17:46:59 1807067 0 1/1/11 scxl.bt BT V1.0.0P1 2010-08-19 08:56:51 444176 0 1/1/11 scxl.fw FW V1.2.0 2010-09-06 16:37:25 159982 0 1/1/11 scxl0.mvr MVR V1.2.0 2010-12-21 17:11:05 8137410 1 1/1/11 scxl1.mvr MVR V1.0.0 2010-09-07 11:55:48 7094783 0

ZXAN#show version-saved slave

PhyLoc FileName VerType VerTag BuildTime VerLenth Active --------------------------------------------------------------------------------

1/1/10 gtgoa.bt BT V1.0.0P1 2010-07-01 13:42:04 326048 0 1/1/10 gtgoa.fw FW V1.2.0 2010-09-06 16:00:35 5437973 0 1/1/10 gtgoa.mvr MVR V1.2.0 2010-09-06 16:00:33 1206069 0 1/1/10 gtgoc.bt BT V1.0.0P1 2010-11-15 14:22:39 315344 0 1/1/10 gtgoc.fw FW V1.2.0 2010-09-06 15:42:25 13888707 0 1/1/10 gtgoc.mvr MVR V1.2.0 2010-09-06 15:42:14 1302608 0 1/1/10 gucd.bt BT V1.0.0P2 2010-12-20 09:05:00 210876 0 1/1/10 gucd.fw FW V1.2.0 2010-12-21 17:18:16 104625 0 1/1/10 gucd.mvr MVR V1.2.0 2010-12-21 17:46:59 1807067 0 1/1/10 scxl.bt BT V1.0.0P1 2010-08-19 08:56:51 444176 0 1/1/10 scxl.fw FW V1.2.0 2010-09-06 16:37:25 159982 0 1/1/10 scxl0.mvr MVR V1.2.0 2010-12-21 17:11:05 8137410 1 1/1/10 scxl1.mvr MVR V1.0.0 2010-09-07 11:55:48 7094783 0

1.9 版本升级

1.10

步骤一. 升级各板卡的boot。

? 通过show card查看板卡当前运行情况,以确定需要升级的板卡slot号。

ZXAN#show card

Rack Shelf Slot CfgType RealType Port HardVer SoftVer Status

------------------------------------------------------------------------------- 1 1 0 PRWG PRWG 0 INSERVICE 1 1 10 SCXL SCXL 0 090600 V1.0.0T10P1 STANDBY 1 1 11 SCXL SCXL 0 090600 V1.0.0T10P1 INSERVICE 1 1 15 GTGO GTGOA 8 080802 V1.0.0T10P1 INSERVICE 1 1 19 GUSQ GUSQ 4 090200 V1.0.0T10P1 INSERVICE

? 通过show version-running命令查询当前版本运行情况,以备验证boot升级是否成功。 ZXAN#show version-running

PhyLoc FileType VerType VerTag BuildTime VerLenth --------------------------------------------------------------------------------

1/1/10 SCXL MVR V1.0.0T10P1 2010-04-14 05:58:06 7035019 1/1/10 SCXL FW V1.0.0T10P1 2010-04-14 00:59:48 159982 1/1/10 SCXL BT V1.0.0T10P1 2010-03-23 09:43:02 437424 1/1/11 SCXL MVR V1.0.0T10P1 2010-04-14 05:58:06 7035019 1/1/11 SCXL FW V1.0.0T10P1 2010-04-14 00:59:48 159982 1/1/11 SCXL BT V1.0.0T10P1 2010-03-23 09:43:02 437424 1/1/15 GTGOA MVR V1.0.0T10P1 2010-04-14 05:24:28 1181492 1/1/15 GTGOA FW V1.0.0T10P1 2010-04-14 00:25:17 5459768 1/1/19 GTGOA BT V1.0.0T10P1 2010-03-23 14:51:01 325808 1/1/19 GUCD MVR V1.0.0T10P1 2010-04-14 23:56:27 520621 1/1/19 GUCD BT V1.0.0T10P1 2010-03-23 09:41:39 320768 ? 通过命令update-boot slotno [slotno id]升级各板卡的boot ZXAN#update-boot slotno 10

................................................................................

................................................................................

......................................................[Successfully]

ZXAN#update-boot slotno 11

................................................................................

................................................................................

......................................................[Successfully] ZXAN#update-boot slotno 15

.................................................................[Successfully] ZXAN#update-boot slotno 19

...........................................[Successfully]

1.11

步骤二. 升级各板卡的cpld/fw

? 通过show updatecpld查看原cpld升级情况,已备后续验证cpld是否升级成功。 ZXAN#show updatecpld

Rack Shelf Slot Updateflag Validflag Version ------------------------------------------------------ 1 1 10 OLD VALID V1.5 1 1 11 OLD VALID V1.5 1 1 15 OLD VALID V1.5 1 1 19 OLD VALID V1.0

? 通过命令update-cpld设置升级cpld标志位(设置标志位成功后,需重启网元/或对应

线卡来完成cpld的升级)

ZXAN#update-cpld slotno 19 swtval 1

%Code 35670: Cpld update flag is set successfully. ZXAN#update-cpld slotno 15 swtval 1

%Code 35670: Cpld update flag is set successfully. ZXAN#update-cpld slotno 11 swtval 1

%Code 35670: Cpld update flag is set successfully. ZXAN#update-cpld slotno 10 swtval 1

%Code 35670: Cpld update flag is set successfully.

? 通过命令查看show updatecpld命令是否下发成功。 ZXAN#show updatecpld

Rack Shelf Slot Updateflag Validflag Version ------------------------------------------------------ 1 1 10 NEW VALID V1.5 1 1 11 NEW VALID V1.5 1 1 15 NEW VALID V1.5 1 1 19 NEW VALID V1.0

Updateflag为NEW表示cpld升级命令下发成功,板卡会在下次启动时进行升级。

? 通过show version-running查看当前fw运行情况,以备验证更新fw是否成功。

ZXAN#show version-running

PhyLoc FileType VerType VerTag BuildTime VerLenth --------------------------------------------------------------------------------

1/1/11 SCXL MVR V1.0.0T10P1 2010-04-14 05:58:06 7035019 1/1/11 SCXL FW V1.0.0T10P1 2010-04-14 00:59:48 159982

1/1/11 SCXL BT V1.0.0T10P1 2010-03-23 09:43:02 437424 1/1/15 GTGOC MVR V1.0.0T10P1 2010-04-14 05:24:28 1181492 1/1/15 GTGOC FW V1.0.0T10P1 2010-04-14 00:25:17 5459768 1/1/15 GTGOC BT V1.0.0T10P1 2010-03-23 14:51:01 325808 1/1/19 GUCD MVR V1.0.0T10P1 2010-04-14 23:56:27 520621 1/1/19 GUCD BT V1.0.0T10P1 2010-03-23 09:41:39 320768 1.12

步骤三. 保存配置,重启网元

ZXAN#write

Building configuration... ..[OK]

ZXAN#reboot

Confirm to reboot? [yes/no]:y

1.13 确认版本升级成功

网元启动成功后,需要验证版本是否升级成功。

? 通过show version-running命令验证各线卡运行版本是否与升级版本一致。 如:

ZXAN#show version-running

PhyLoc FileType VerType VerTag BuildTime VerLenth --------------------------------------------------------------------------------

1/1/10 SCXL MVR V1.2.0 2010-12-21 17:11:05 8137410 1/1/10 SCXL FW V1.2.0 2010-12-21 17:11:14 143001 1/1/10 SCXL BT V1.0.0P1 2010-08-19 08:56:51 444176 1/1/11 SCXL MVR V1.2.0 2010-12-21 17:11:05 8137410 1/1/11 SCXL FW V1.2.0 2010-12-21 17:11:14 143001 1/1/11 SCXL BT V1.0.0P1 2010-08-19 08:56:51 444176 1/1/15 GTGOC MVR V1.2.0 2010-12-21 17:52:40 1888908 1/1/15 GTGOC FW V1.2.0 2010-12-21 17:24:14 1518290 1/1/15 GTGOC BT V1.0.0P1 2010-11-15 14:22:39 315344 1/1/19 GUCD MVR V1.2.0 2010-12-21 17:46:59 1807067 1/1/19 GUCD BT V1.0.0P2 2010-12-20 09:05:00 210876 ? 通过show update-cpld验证cpld是否升级成功 ZXAN#show updatecpld

Rack Shelf Slot Updateflag Validflag Version ------------------------------------------------------ 1 1 10 OLD VALID V1.1 1 1 11 OLD VALID V1.1 1 1 15 OLD VALID V2.0 1 1 19 OLD VALID V1.0

注:

1. 网元/线卡每次启动时会自动去调用mvr版本文件。因此,对于mvr版本文件只需下载

至主控板flash中即可。

2. 具体对应的cpld版本号,请参阅各发布版本的“版本发布升级说明”。

1.14

1.15

版本回退

版本回退判断标准

如果没有在规定时间内完成升级或升级后在规定时间内出现重大故障,造成用户业务中断不能使用的,必须将版本回退到原先版本。

1.16

版本回退方法

版本回退方法,与版本升级方法同理,具体请参阅本文中“升级步骤”。

1.6 升级测试

业务测试:

通过ONU下挂用户进行上网、IPTV及VOIP等综合业务测试,业务正常。 网管测试:

网管连接正常,网管可正常同步和配置数据,网管上可以看到网元上报的告警。

1.7 注意事项

请参阅各发布版本的“版本发布升级说明”。

1.8 升级版本需配套使用

请参阅各发布版本的“版本发布升级说明”。

1.9 检查单

1) 宽带上网业务是否正常 2) IPTV业务是否正常

3) 语音同一PON口下呼叫是否正常 4) 语音不同PON口下呼叫是否正常 5) 语音到PSTN呼叫是否正常

6) 主备通讯是否正常(如果有备用主控板) 7) 主备倒换是否正常(如果有备用主控板) 8) 网管到网元通讯是否正常 9) 网管命令是否能正常执行 10) 是否有新增告警