爱立信LTE告警 下载本文

内容发布更新时间 : 2024/11/16 6:58:32星期一 下面是文章的全部内容请认真阅读。

Auto-Configuration of Board Not Possible Automatic CV Creation Failed BatteryBackupTimeTooShort

BatteryMissing

BatteryVoltageTooLowMainLoadDisconnected BatteryVoltageTooLowPrioLoadDisconnected Board Overheated CalibrationFailure

CircuitBreakerTripped

Clock Calibration Expiry Soon Configuration Version Corrupt Contact to Default Router 0 Lost Contact to Default Router 1 Lost Contact to Default Router 2 Lost Credentials Enrollment Fault Credentials Validity Fault CurrentTooHigh Disconnected Disk Volume C Full

Disk Volume D Full

Duplicate IP Address Fault

Emergency Unlock of Software Licensing EnclosureDoorOpen

EnclosureProductDataMismatch EnclosureSmoke

EnclosureSmokeDetectorFailure ET IP Hardware Fault ExternalAlarm

ExternalLinkFailure FanFailure

FeatureResourceMissing FeatureResourceMissing FeatureResourceMissing File System Diagnostic Error GeneralHwError GeneralSwError GeneralSwError

Gigabit Ethernet Link Fault

无法自动识别板件 自动创建CV失败

报警表明电池的容量是不够的,应更换电池,以满足所需时间

由于电源损坏或者电缆不通而产生 低电压至主控单元失效 低电压至电池单元失效 板件过热

由于外界信号的突发干扰,导致校准信号异常,也有可能是内部干扰导致 断路器跳闸

由于同步问题时钟校准即将失效 CV损坏

失去与默认路由0的连接 失去与默认路由1的连接 失去与默认路由2的连接 证书登入错误

证书即将在7天内过期 电流过高

各个硬件如果失去连接即产生此告警

如果Main Processor(主处理器MP)的C卷上存储的数据过多,会导致该卷的可用空间耗尽或几乎耗尽,此时系统会发出Disk Volume C Full告警如果Main Processor(主处理器MP)的D卷上存储的数据过多,会导致该卷的可用空间耗尽或几乎耗尽,此时系统会发出Disk Volume D Full告警重复IP地址冲突

当激活紧急状态时,会产生这个alarm 外部门开启

外部产品的信息空缺或者不匹配 检测到机柜里有烟雾 外部烟雾感应器实效 以太网传输硬件故障

超过系统对外部设备监控的极限或者外部设备有问题

至少一个邻区的X2链接断开 风扇故障

特性相关资源丢失,一般由于license缺失 特性相关资源丢失,一般由于license缺失 特性相关资源丢失,一般由于license缺失 文件系统诊断错误 一般性硬件单元故障 一般性软件故障 一般性软件故障

千兆以太网传输上的没有速率,或者一直以极低

速率传输

Gigabit Ethernet Link Redundancy Fault 两个千兆以太网连接冗余设备中的一个故障 GpsConnectivityDownstreamFault GPS下游连接故障

在GPS和XMU之间的通信出现问题,可能由于电

GpsHardwareFault

缆断了,电缆无法连接,或硬件问题

Hardware Failure Imminent 硬件错误预警

HighOperatingTemperatureMainLoadDisconnected 高温至主控单元失效 HwFault IKE Peer Not Reachable InconsistentConfiguration InconsistentConfiguration InsufficientBatteryCharging Inter-PIU Link Fault

Invalid Ethernet Optical Module IPsec Certificate Expiry

IPsec Certificate Fault

Large Number of Counters License Key File Fault LinkFailure Local AA DB Installation Fault Loss of Synch Reference Redundancy

Loss of Tracking 硬件故障 IKE对端无反馈或者鉴权失败,或者没有协议选择 配置不一致 配置不一致 10天内电池一直充电不满

Inter-PIU的连接电缆缺失,有问题或者没有正确

连接

以太网光纤模块不可用或者未安装

在IpSec MO下定义的certExpirWarnTime过期后,

IPSec证书将过期

在IpSec MO下定义的certExpirWarnTime过期后,

IPSec证书将过期

激活计数器数量多 安装的许可秘钥文件不可用

告警原因有可能是工程阶段某些站点安装调测未

完成导致的。也有可能是光纤/光模块或者DU/RU

的硬件端口故障

本地AA数据库安装错误

此告警是次生告警,是由MO Synchronization发

出。可以参考主告警:

TU Synch Reference Loss of Signal

Network Synch Time from GPS Missing

Loss of Tracking

Synch Reference Path HW Fault

Packet Server Availability Fault

Synch Reference Not Reliable

Sync Reference PDV Problem

SDH 相关告警: Loss of Signal, Loss of Frame, MS Alarm Indication Signal, MS Degraded Signal, MS

Excessive Bit Error Rate, Plug-In Unit HW Failure, or

ET Hardware Fault

IP同步源: NTP Server Reachability Fault, or Gigabit

Ethernet Link Fault

此告警的后果是,同步源的数量减少或者只剩一个同步源,如果最后一个同步源也丢失,系统时钟会进入”holdover mode”,然后是”free-running

mode”,这样就不能满足无线模块所要求的时钟精度。

这个是一个主告警,和Synchronization· MO相关。

当TU系统的时钟进入失步状态,出现此告警,同

时syncRefStatus变为LOSS_OF_TRACKING LossOfMains 供电故障产生 LowBatteryCapacity 电池容量低于预期,断电时间比预期时间短。 Maximum Number of Counters Exceeded 计数器数量超过最大限额

当TU没接收到1PPS或者接收到大量GPS的信息

Network Synch Time from GPS Missing

时产生

NoContact 相关资源缺失或者链接没有建议

这是一个主要告警,是由MO IpSyncRef触发的,当NTP(Network Time Protocol) 客户端检测到NTP服

NTP Server Reachability Fault

务器为 not reachability 时,产生该告警. 同步参考信号的状态会变为NOT_REACHABLE

NTP server无法完全正确同步时或者当系统的始

NTP System Time Sync Fault

终被改变超过1000s时产生

NTP System Time Sync Problem 当系统时间以大于2s但小于1000s递进时产生 NumberOfHwEntitiesMismatch 硬件实体数量不匹配 OperatingTemperatureTooHighBatteryDisconnected 高温至电池单元失效 OperatingTemperatureTooHighCapacityReduced 操作温度过高,容量减小 OperatingTemperatureTooHighNoService 操作温度过高,无法服务 OperatingTemperatureTooLowCapacityReduced 操作温度过低,容量减小 OperatingTemperatureTooLowCommunicationLost 操作温度过低,失去通信

当包同步源存在 “Server Availability Fault”告警

Packet Server Availability Fault 时。根据packetSyncStatus的值可以指出相应的告

警原因

Password File Fault 密码错误

当所有可恢复的操作已经在PIU上操作过,当PIU

Plug-In Unit General Problem

至少缺失5分钟以上产生

Plug-In Unit HW Failure 插入单元硬件错误 Power Feeding Fault 电源供给故障 PowerFailure 电源故障 ProblemsToScheduleSiMessages 系统消息量太大以至于无法调度 Remote IP Address Unreachable 远端IP地址不可达 ResourceAllocationFailure 资源配置或调配错误

资源配置失败,分配失败,资源冲突或者软硬件之

ResourceConfigurationFailure

间不匹配

资源配置失败,分配失败,资源冲突或者软硬件之

ResourceConfigurationFailure

间不匹配

资源配置失败,分配失败,资源冲突或者软硬件之

ResourceConfigurationFailure

间不匹配

RetFailure 配置文件错误,无法移动天线或者有干扰 RunningOnBatterySupply 电池供电运行中 Security Level Fault 当前操作安全级别低于站点要求安全级别

? 由硬件故障等其他故障引起的小区降质,有其他相关主告警,本告警为伴随告警。主要告警包

ServiceDegraded

括:HwFault, PowerFailure, LinkFailure, InconsitentConfiguration,