内容发布更新时间 : 2024/11/20 15:28:07星期一 下面是文章的全部内容请认真阅读。
枣庄矿业(集团)有限责任公司田陈富源煤矸石电厂2×200MW发电机组扩建工程
环境影响报告书
简 本
建设单位:滕州富源低热值燃料热电有限公司 评价单位:环境保护部环境发展中心
二00九年十二月
目 录
1环评工作总体设计 ··················· 1
1.1评价标准 ·························· 1
1.2环评工作程序 ························ 2 1.3公众参与开展情况 ······················ 2
2工程概况及污染因素分析 ················ 3
2.1现有工程 ·························· 3 2.2 扩建工程 ························· 5
3环境质量现状调查与评价 ················ 8
3.1环境空气质量现状 ······················ 8
3.2 水环境质量现状 ······················ 9 3.3 声环境质量现状 ······················ 9 3.4 生态环境水平 ······················· 9
4环境影响预测及评价 ·················· 9
4.1环境空气影响预测及评价 ··················· 9
4.2地表水环境影响分析 ····················· 10 4.3噪声环境影响预测评价 ···················· 10 4.4灰渣综合利用影响分析 ···················· 11 4.5输煤系统及煤场环境影响 ··················· 11 4.7 生态影响分析 ······················· 11
5环境风险评价 ····················· 12 6环境污染防治措施与对策 ················ 12
6.1烟气治理措施 ························ 12 6.2废水治理措施 ························ 13 6.3噪声治理设施 ························ 13 6.4固废综合利用措施和贮运污染防治对策 ············· 14 6.5生态保护措施 ························ 14
7规划与产业政策相符性分析 ··············· 14
7.1规划符合性分析 ······················· 14 7.2产业政策符合性 ······················· 15
8总量指标来源 ····················· 15 9环境影响评价主要结论 ················· 15
I
1环评工作总体设计
1.1评价标准
1.1.1环境质量标准
(1)环境空气
扩建工程所在区域环境空气执行《环境空气质量标准》(GB3095-1996)及修改通知单二级标准.
(2)水环境
与扩建工程相关的地表水体北河执行《地表水环境质量标准》(GB3838-2002)Ⅲ类标准;区域地下水水质执行《地下水质量标准》(GB/T14848-93)中Ⅲ类标准。
(3)声环境
区域声环境执行《声环境质量标准》(GB3096-2008)2类标准。 1.1.2污染物排放标准
(1)大气污染物
锅炉废气污染物排放执行《火电厂大气污染物排放标准》 (DB37/ 664—2007)中第3时段燃煤锅炉标准,现有工程执行第2时段燃煤锅炉标准,厂界无组织排放粉尘执行《大气污染物综合排放标准》(GB16297-1996)无组织排放监控浓度限值要求。
(2)水污染物
扩建工程正常工况下生产废水全部回用于矿区洗煤厂,生活污水进入蒋庄煤矿污水处理站处理后排入北河,厂内生活污水处理后执行《污水综合排放标准》(GB8978-1996)三级标准,污水处理站出水执行《山东省南水北调沿线水污染物综合排放标准》(DB37/599-2006)重点保护区域标准限值。
(3)噪声
扩建工程厂界执行《工业企业厂界环境噪声排放标准》(GB12348-2008)中的2类标准,铁路边界噪声执行《铁路边界噪声限值及其测量方法》(GB12525-90)中铁路边界噪声限值,施工期噪声执行《建筑施工场界噪声限值》(GB12523-90)。
1