LTE测试指导(CMW500) 下载本文

内容发布更新时间 : 2024/5/11 20:17:01星期一 下面是文章的全部内容请认真阅读。

测试标准:

Table 6.3.4.2.1.5-1: PRACH time mask Transmit OFF power Expected PRACH Transmission ON Measured power ON power tolerance ± 7.5dB ± 7.5dB ± 7.5dB ± 7.5dB ± 7.5dB ± 7.5dB -1 dBm -1 dBm -1 dBm -1 dBm -1 dBm -1 dBm Channel bandwidth / Output Power [dBm] / measurement bandwidth 1.4 MHz 3 MHz 5 MHz 10 MHz 15 MHz 20 MHz ? -48.5 dBm

3.8、SRS时间模板(6.3.4.2.2)

测试步骤:

1) LTE Signaling →Config → Physical Cell Setup。

2) 点击LTE Signaling,选择Config,进入Uplink Power Control,设置Active TPC Setup为Constant Power。 3) 如果不支持Advance PRACH/OL Power Setting,Open Loop Nominal 根据下表进行设置。

Bandwidth 1.4M 3M 5M 10M Open loop Nominal Power(dBm) 8.5 9 11 14

15M 20M 16 17 支持Advance PRACH/OL Power Setting,Open Loop Nominal为默认值。 4) 将RS EPRE 设置为–85 dBm/15 KHz。

5) 将LTE SRS Measurement Task 添加到CMW500 的任务栏中(按“Measure” 软件选择)并且按config选择

scenario为Combined Signal Path, controlled by LTE Sig1. 默认触发方式为IF Power触发。 6) 打开小区,让终端同CMW500 建立RMC 连接。

7) 激活Downlink MAC Padding at LTE Signaling→Connection, 然后将UL RMC 设置为0。

8) 按ON/OFF 按键激活SRS 测量。

测试标准:

Table 6.3.4.2.2.5-1: SRS time mask Transmit OFF power Expected SRS Transmission ON Measured power ON power tolerance ± 7.5dB ± 7.5dB ± 7.5dB ± 7.5dB ± 7.5dB ± 7.5dB -2.6 dBm -2.6dBm -2.6 dBm -2.6 dBm -2.6 dBm -2.6 dBm Channel bandwidth / Output Power [dBm] / measurement bandwidth 1.4 MHz 3 MHz 5 MHz 10 MHz 15 MHz 20 MHz ? -48.5 dBm

3.9、绝对功率控制容限(6.3.5.1)

测试步骤:

1) 设置功率控制模式,在LTE Signaling界面下点击Config按钮,在Uplink Power Control下选择TX Power Control(TPC),Active TPC Setup选择为Constant Power模式。将Open Loop Nominal Power设为Point1对应的功率值。

2)点击LTE Signaling,选择Config,进入Connection界面下激活Keep RRC Connection,使能RRC空闲模式。

3)注册连接,点击Measure,选择LTE1 Multi Eval进入测试界面。 4)点击Multi Evaluation,点击Assign Views,选择EVM。 5)读取Test Point1 对应的Tx Power

6)断开连接,将Open Loop Nominal Power设为Point2 对应的功率值。 7)重复步骤1)-5)读取Test Point 2 对应的Tx Power。

8)如果不支持Advance PRACH/OL Power Setting,Test Point值根据下表进行设置

Bandwidth 1.4M 3M 5M 10M 15M 20M Open loop Nominal Power(dBm) Open loop Nominal Power(dBm) (Test Point1) -15 -11 -9 -6 -4 -3 Test Point1 -105dBm (Test Point2) -3 1 3 6 8 9 Test Point2 -93dBm 支持Advance PRACH/OL Power Setting,PO Nominal PUSCH根据下表进行设置 Parameter PO Nominal PUSCH

测试标准:

Table 6.3.5.1.5-1: Absolute power tolerance: test point 1 1.4 MHz Expected Measured power Normal conditions Power tolerance Expected Measured power Extreme conditions Power tolerance Channel bandwidth / expected output power (dBm) 3.0MHz -10.8dBm ±10.0dB -10.8dBm ±13.0dB 5 MHz -8.6dBm ±10.0dB -8.6dBm ±13.0dB 10 MHz -5.6dBm ±10.0dB -5.6dBm ±13.0dB 15 MHz -3.9dBm ±10.0dB -3.9dBm ±13.0dB 20 MHz -2.6dBm ±10.0dB -2.6dBm ±13.0dB -14.8dBm ±10.0dB -14.8dBm ±13.0dB Table 6.3.5.1.5-2: Absolute power tolerance: test point 2 1.4 MHz Expected Measured power Normal conditions Power tolerance Expected Measured power Extreme conditions Power tolerance ± 13.0dB ±13.0dB ± 13.0dB ±13.0dB ±13.0dB ±13.0dB -2.8 dBm 1.2dBm 3.4dBm 6.4dBm 8.2dBm 9.4dBm ± 10.0dB ±10.0dB ±10.0dB ±10.0dB ±10.0dB ±10.0dB -2.8 dBm 1.2dBm 3.4dBm 6.4dBm 8.2dBm 9.4dBm Channel bandwidth / expected output power (dBm) 3.0 MHz 5 MHz 10 MHz 15 MHz 20 MHz

3.10、相对功率控制容限(6.3.5.2)

终端的功率变化可以由功率控制或者RB 变化引起,基于这个原因本测试设计了三种测试场景来验证LTE终端的相对功率变化情况:

功率上升测试(TS 36.521-1, 图6.3.5.2.4.2-1) 功率降低测试(TS 36.521-1, 图6.3.5.2.4.2-2)

功率交替变化测试(TS 36.521-1, 图6.3.5.2.4.2-5).

根据RB 变化的不同时间点,功率上升测试和功率下降测试又各自定义了三种模式,分别为模式A,模式B,模式C。 测试步骤:

1、 功率上升测试

1) 注册、连接。进入Multi Evaluation界面,勾选Power Monitor。

2) 功控测量是一个瞬间的过程,功控不能不处于连续测试的模式下,将Repetition设置为Single Slot。

Statistic Count(Power)设置为1 Subframes。对于FDD,将Subframes Offset设置为0,No. of Subframes to 80。对于TDD,将Subframes Offset设置为0,No. of Subframes to 100,Measure Subframe为2。

3) 进入Trigger→Trigger Source设置触发方式为TPC触发(LTE Sig1:TPC trigger)。

4) 设置上行RMC:将RB设置为1, 调制方式设置为QPSK, 将Active TPC Setup 设置为Closed Loop,将

Closed- Loop Target Power设置为–36.8 dBm ,确保终端的实际输出功率在–36.8 dBm±- 3.2 dB 范围内。

5) 将Expected Nom. Power 设置为–18 dBm ,并且将User Margin 设置为0 dB。

6) 按ON/OFF 按钮初始化测量,此时测量模块会等待TPC 消息来触发测量,将Active TPC Setup 设置为

User-Defined Single Pattern,并且将Length 设置为10 (FDD) / 4 (TDD) ,TPC的值都设置为+1。然后按execute 按键下发TPC 命令。

7) 对于TDD,重复步骤2 和3 (更改Expected Nom. Power)得到测量结果。

8) 在连接界面, 将Scheduling Type 从RMC 修改为User Defined, TTI Based,然后按Edit All 来修改

UL→ TTI 设置(以20M为例,其余带宽参照表6.3.5.2-1)

Table 6.3.5.2-1

Bandwidth #RB 1.4M 6 3M 4 5M 20 10M 15M 20M 25 50 75