Brocade 光纤交换机常用命令 下载本文

内容发布更新时间 : 2024/7/1 7:51:13星期一 下面是文章的全部内容请认真阅读。

Brocade 光纤交换机常用命令 标签: Brocadesan交换机命令 2013-12-24 10:19 2062人阅读 评论(0) 收藏 举报 分类: San IBM的双机双柜,两光纤交换机分别引一根光纤到另一楼光纤交换机,插上无反应,后得知需要更改交换机的domain id 默认出厂为1。需改为不同号。下面是博科的交换机命令转。http://maka113.blog.163.com/blog/static/12110329720129254116675/ Brocade SAN交换机常用命令 使用电脑连接管理网口,默认IP地址为:192.168.0.1,掩码:255.255.255.0 默认用户名:admin,默认密码password 1. switchStatusShow 查看交换机的总体健康状态 switch:admin>switchstatusshow Switch Health Report Switch Name: SWFCR IP address: 10.33.54.176 SwitchState: MARGINAL Duration: 863:23 Power supplies monitor MARGINAL Temperatures monitor HEALTHY Fans monitor HEALTHY WWN servers monitor HEALTHY Standby CP monitor HEALTHY Blades monitor HEALTHY Flash monitor HEALTHY Marginal ports monitor HEALTHY Faulty ports monitor HEALTHY Missing SFPs monitor HEALTHY All ports are healthy switch:admin> 2. switchShow 查看交换机基本配置信息 Enter the switchShow command, which displays the following information for a switch: - switchname - The switch name. - switchtype - The switch model and firmware version numbers. - switchstate - The switch state: Online, Offline, Testing, or Faulty. - switchrole - Displays the switch role: Principal, Subordinate, or Disabled. - switchdomain - Displays the switch Domain ID. - switchid - The embedded port D_ID of the switch. - switchwwn - The switch World Wide Name. - switchbeacon - The switch beaconing state: either ON or OFF. The switchShow command also displays the following information for ports on the specified switch: - Module type - The SFP type if an SFP is present. - Port speed - The speed of the Port (1G, 2G, 4G, N1, N2, N4, or AN). The speed can be fixed, negotiated, or auto-negotiated. - Port state - The port status. - Comment - About the port. This section may be blank or display the WWN for an F_Port or an E_Port, the trunking state, or upstream or downstream status 3. portShow 查看端口状态 switch:admin>switch:user>portshow 0 portName: portHealth: OFFLINE Authentication: None portDisableReason: None portCFlags: 0x1 portFlags: 0x4001 PRESENT U_PORT LED portType: 4.1 portState: 2 Offline portPhys: 2 No_Module portScn: 0 port generation number: 0 portId: 010000 portIfId: 43020020 portWwn: 20:00:00:60:69:00:02:53 portWwn of device(s) connected: Distance: normal portSpeed: N2Gbps LE domain: 0 Interrupts: 0 Link_failure: 0 Frjt: 0 Unknown: 0 Loss_of_sync: 0 Fbsy: 0 Lli: 0 Loss_of_sig: 0 Proc_rqrd: 0 Protocol_err: 0 Timed_out: 0 Invalid_word: 0 Rx_flushed: 0 Invalid_crc: 0 Tx_unavail: 0 Delim_err: 0 Free_buffer: 0 Address_err: 0 Port part of other ADs: Yes 4. fanShow 查看交换机散热风扇的状态 Enter the fanShow command: switch:admin>fanshow Fan 1 is OK speed is 7010 RPM Fan 2 is OK speed is 7180 RPM Fan 3 is OK speed is 7068 RPM Fan 4 is OK speed is 7116 RPM Fan 5 is OK speed is 7155 RPM Fan 6 is OK speed is 7001 RPM switch:admin> 5. psShow 查看交换机的电源状态 注:如果安装FR4-18i、FC4-16IP、FC10-6、FC8-48板,需要满配4个电源 Enter the psShow command: switch:admin>psshow Power Supply #1 is OK 0335,FF2Z0007161,60-0000739-02, B,,DCJ3002-01P, B,FF2Z0007161 Power Supply #2 is faulty 0335,FF2Z0007176,60-0000739-02, B,,DCJ3002-01P, B,FF2Z0007176 switch:admin> 6. tempShow 查看交换机的环境温度 Enter the tempShow command: switch:admin>tempshow Index Status Centigrade Fahrenheit ---------------------------------------------------- 1 OK 21 70 2 OK 22 72 3 OK 29 84 4 OK 24 75 5 OK 25 77 switch:admin> 7. errDump、errShow、errClear 查看交换机的内部消息日志 To display the system message log, with no page breaks Enter the errDump command. To display the system message log one at a time Enter the errShow command. To clear the system message log